Home / How to Select the Right Ceramic Fiber Board for Your Furnace Type
Ceramic Fiber Module Installation Guide
Proper installation is key to achieving the full energy savings of ceramic fiber modules. Follow these steps for a secure, long‑lasting lining.
Step‑by‑Step Installation
- Preparation: Clean the furnace shell and verify anchor positions (welding or screw locations).
- Anchor Installation: Weld or screw anchors (e.g., 304 or 310 stainless steel) per the layout drawing.
- Module Placement: Press modules firmly onto anchors, ensuring fold lines are oriented towards the heat source. Stagger joints between rows.
- Sealing & Curing: For high-velocity areas, apply a rigidizer coating. Follow the recommended heat‑up schedule to avoid thermal shock.
Common Mistakes to Avoid
- Leaving gaps between modules – creates heat shortcuts and reduces insulation efficiency.
- Over‑compressing modules – reduces the material’s insulating value.
- Ignoring anchor corrosion – rust can lead to module detachment.
- Skipping the rigidizer in high‑velocity gas zones – leads to surface erosion.
Tip: If you are retrofitting an older furnace, inspect the steel shell for flatness before installing anchors. Any major deformations should be corrected.
Need detailed technical support? Contact us for a free consultation and layout guidance.
Let's Innovate Together
We have a dedicated team ready to help you with your most challenging projects. Whether you need a custom furnace chamber, a complex shape, or simply expert advice — contact us today. We're ready for the challenge.